Water Cut-Off & Flow Rate Adjustor
Water Cut-Off & Flow Rate Adjustor
C-264-1
Model No. | C-264-1 |
Description | Water Cut-Off & Flow Rate Adjustor |
Standard |
|
WATER HAMMER EFFECT TEST REPORT
Test Model | Water Cut-off & Flow Rate Adjuster | Star Time | Inspection Date | 2018-07-27 18:49:02 |
||||
Data | Upper limit of Cycle pressure | 10.5 | Upper Pulse time(s) | 1 | Set Times | 100,000 | Test Quantity | 1 piece |
Lower limit of Cycle pressure | 0 | Lower Pulse time(s) | 1 | Current Times | 100,000 | Name of Tester | ZHANG GUANG JI | |
Test Result: | ||||||||
WATER HAMMER TEST CHART |
PRESSURE TEST REPORT
Name of Tester | ZHANG GUANG JI | Inspection Date | 2018-07-12 | ||
Pressure Test (bar) | 15 | Model Specification | Water Cut-Off & Flow Rate Adjuster | ||
Holding Pressure Start (bar) |
15 | Holding Pressure End (bar) |
15.3 | Pressure Hold Time | 90 |
Start Time | 12:55:16 | End Time | 14:25:18 | ||
Boost rate (bar/min) | 29 | Test Result | |||
BURST TEST REPORT
Test Model | Water Cut-Off & Flow Rate Adjuster | Inspection Date | 2018-07-13 | ||
Test Purpose | Burst test | Test Quantity | 1 piece | ||
Holding Pressure Start (bar) |
None | Holding Pressure End (bar) |
None | Name of Tester | ZHANG GUANG JI |
Star time | 08:48:32 | End Time | 08:50:40 | Burst Pressure (bar) | 40.5 |
Holding Pressure 1 | 10 bar | Pressure Hold Time 1 | 5 second | Boost Rate (bar/min) | 19.1 |
Holding Pressure 2 | 20 bar | Pressure Hold Time 2 | 5 second | ||
Test Result: | |||||